N1MM settings

I am using the FT-857D in combination with the MicroHam USB III Interface.


The microHAM USB Device Router is configured in the following way:




How to configure N1MM?

I have not managed to find a common setup for SSB and CW.
A common setting would look like this:



This works for SSB, but for CW the TRX is keyed with a continuous tone instead of CW.

For CW, I need to disable the PTT:




Audio Settings:






Window -> CW Reader:







Digital Modes by means of Fldigi

Definition of Fldigi usage in N1MM (copy fldigi.exe to the N1MM user directory):





Fldigi settings:





Save the configuration settings using the fldigi
Configure > Save Config menu item.